Linked Data API

Show Search Form

Search Results

1138096
star this property registered interest false more like this
star this property date less than 2019-07-10more like thismore than 2019-07-10
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, how many new models of boilers introduced since October 2017 have been tested and submitted to the BRE to comply with the new Boiler Plus regulations. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 275657 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-07-16more like thismore than 2019-07-16
unstar this property answer text <p>The testing and registration of new models of boiler by the Buildings Research Establishment (BRE) is not part of compliance with the Boiler Plus regulations.</p><p>In order to comply with the Boiler Plus regulations, the boiler unit must meet Energy-related Products (ErP) standards with a minimum ErP efficiency of 92%. Compliance is carried out by Notified Bodies, as defined by EU Directive 92/42/EEC: Hot Water Boilers. A list of Notified Bodies can be found at the following URL: <a href="https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fec.europa.eu%2Fgrowth%2Ftools-databases%2Fnando%2Findex.cfm%3Ffuseaction%3Ddirective.print%26refe_cd%3D92%252F42%252FEEC&amp;data=02%7C01%7CRosalyn.Tandy%40beis.gov.uk%7C6619f9a1216a41569f5d08d6e8c8cd56%7Ccbac700502c143ebb497e6492d1b2dd8%7C0%7C0%7C636952346463943182&amp;sdata=gssTJ8R70WjIZLq8bys1I8226ZrXkxW4OvQngs%2BMl1Y%3D&amp;reserved=0" target="_blank">http://ec.europa.eu/growth/tools-databases/nando/index.cfm?fuseaction=directive.print&amp;refe_cd=92%2F42%2FEEC</a></p><p>The BRE maintains the Standard Assessment Procedure (SAP) for the energy performance of homes. For the purposes of SAP, boiler efficiency values are derived using a calculation known as Seasonal Efficiency of Domestic Boilers in the UK (SEDBUK). This is the value that is recorded by BRE in the Product Characteristics Database.</p>
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-07-16T16:39:25.477Zmore like thismore than 2019-07-16T16:39:25.477Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1136865
star this property registered interest false more like this
star this property date less than 2019-07-04more like thismore than 2019-07-04
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to his Answer 11 June 2019 to Question 258961 on Boilers, whether the variables listed in that answer apply to the heating system and not the boiler. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 273312 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-07-10more like thismore than 2019-07-10
unstar this property answer text <p>The variables stated in the answer to Q258961 on 11 June 2019, apply to the in situ test context for the boiler, not to the heating system. The required test conditions for the boiler are described in BS 15502-1, sections 8.1.1 and 8.1.2, unless otherwise specified elsewhere in the standard for specific cases. These conditions include for example requirements on the preparation of test gases, test pressures, test room ventilation, ambient temperature, protection from solar radiation, physical mounting conditions, measurement conditions and tolerances, insulation of the test rig, establishment of thermal equilibrium, conditional control settings and several other similar items requiring closely controlled test room conditions.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-07-10T11:26:15.443Zmore like thismore than 2019-07-10T11:26:15.443Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1136866
star this property registered interest false more like this
star this property date less than 2019-07-04more like thismore than 2019-07-04
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to the Answer of 25 June 2019 to Question 266632 on Boilers, if he will publish the (a) country and (b) organisation that each of the 34 members of the CEN committee comes from. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 273313 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-07-10more like thismore than 2019-07-10
unstar this property answer text <p>A list of the CEN committee members can be found here:</p><p><a href="https://standards.cen.eu/dyn/www/f?p=CENWEB:5" target="_blank">https://standards.cen.eu/dyn/www/f?p=CENWEB:5</a>.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-07-10T11:26:34.457Zmore like thismore than 2019-07-10T11:26:34.457Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1136867
star this property registered interest false more like this
star this property date less than 2019-07-04more like thismore than 2019-07-04
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to his Answer or 19 June 2019 to Question 266634, Boilers, what information his Department holds on any requirements to disable or remove any parts of the boiler in order to perform or complete the test. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 273314 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-07-10more like thismore than 2019-07-10
unstar this property answer text <p>As stated in the Answer of 19 June 2019 to Question 266634, test conditions are specified in BS EN 15502-1 to ensure that the test results are repeatable and comparable. For example section 8.1.2.5 prescribes the requirement for tests to take place under thermal equilibrium conditions, with precautions taken to prevent thermostats or adjustable controls or an electronic temperature control system operating and affecting the gas rate, unless necessary for the specific test being conducted. The standard requires these precautions, where necessary, rather than stating an absolute requirement to disable or remove such boiler controls.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-07-10T11:26:46.12Zmore like thismore than 2019-07-10T11:26:46.12Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1133257
star this property registered interest false more like this
star this property date less than 2019-06-19more like thisremove minimum value filter
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to the Answer of 11 June 2019 to Question 258961, which body determines the tests on domestic boilers, and what organisations are represented by that body. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 266632 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-06-25more like thismore than 2019-06-25
unstar this property answer text <p>The test for the energy efficiency of boilers is set by CEN, a European Standardisation Organisation. Its national members are the national standardization bodies of 28 European Union countries, the Republic of North Macedonia, Serbia, Turkey, Iceland, Norway and Switzerland.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-06-25T10:26:17.16Zmore like thismore than 2019-06-25T10:26:17.16Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1133258
star this property registered interest false more like this
star this property date less than 2019-06-19more like thisremove minimum value filter
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to the Answer of 11 June 2019 to Question 258965, how test conditions for domestic boilers differ from real world in situ conditions. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 266633 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-06-25more like thismore than 2019-06-25
unstar this property answer text <p>The test conditions in labs for domestic boilers assume steady state operation, weighted by full and part power measurements. The energy ratings given to boilers are therefore intended to provide a fair basis for comparison of the energy efficiency of different models. The wide variation in the energy efficiency of buildings that boilers are installed in and in user behaviours makes it difficult to consistently test boiler efficiency in real life conditions.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-06-25T10:26:23.757Zmore like thismore than 2019-06-25T10:26:23.757Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter
1133259
star this property registered interest false more like this
star this property date less than 2019-06-19more like thisremove minimum value filter
star this property answering body
Department for Business, Energy and Industrial Strategy more like this
star this property answering dept id 201 more like this
unstar this property answering dept short name Business, Energy and Industrial Strategy more like this
star this property answering dept sort name Business, Energy and Industrial Strategy more like this
star this property hansard heading Boilers remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Business, Energy and Industrial Strategy, pursuant to the Answer of 11 June 2019 to Question 258965, whether test conditions for domestic boilers allow for any features or functions of those boilers to be changed or disabled during the test. more like this
star this property tabling member constituency Stroud more like this
star this property tabling member printed
Dr David Drew more like this
star this property uin 266634 more like this
star this property answer
answer
star this property is ministerial correction false more like this
star this property date of answer less than 2019-06-25more like thismore than 2019-06-25
unstar this property answer text <p>The required test conditions are given in sections 8.1.1 and 8.1.2 of BS EN 15502-1. These include required fuel characteristics, control mode settings, etc. to ensure that the test results are repeatable and comparable. Limitations are stated, for example section 8.1.2.5 prescribes the requirement for tests to take place under thermal equilibrium conditions, with precautions taken to prevent thermostats or adjustable controls or an electronic temperature control system operating and affecting the gas rate, unless necessary for the specific test being conducted.</p> more like this
star this property answering member constituency Kingswood more like this
star this property answering member printed Chris Skidmore more like this
star this property question first answered
less than 2019-06-25T10:26:29.537Zmore like thismore than 2019-06-25T10:26:29.537Z
star this property answering member
4021
star this property label Biography information for Chris Skidmore more like this
star this property tabling member
252
unstar this property label Biography information for Dr David Drew remove filter