hansard heading Buildings: Insulation more like this
house id 1 more like this
legislature
25259
pref label House of Commons more like this
question text To ask the Secretary of State for Housing, Communities and Local Government, whether Class B High Pressure Laminate cladding with combustible insulation can be reused on a building in the event that the combustible insulation is replaced. more like this
tabling member constituency Croydon North more like this
tabling member printed
Mr Steve Reed more like this
uin 280244 more like this
answer
answer
is ministerial correction false more like this
date of answer less than 2019-07-25more like thismore than 2019-07-25
answer text <p>The Department published in April 2019 a Frequently asked Question on the Government website one of which answer the question “How do the Building (Amendment) Regulations 2018 affect buildings undergoing remediation?”</p><p>The requirement is that building work on such buildings must be carried out so that only materials which achieve European Classification A1 or A2-s1, d0 become part of an external wall or specified attachment (as defined in regulation 2) unless covered by one of the exemptions in the regulations.</p><p>This means that materials which are already part of the external wall, or are existing specified attachments, and are not becoming part of the wall are not covered by the ban (unless there is a change of use). However, during this process care must be taken to ensure that the building is no less compliant in relation to building regulation requirements than before the work was carried out (e.g. cavity barrier).</p><p>The full list of frequently asked questions is available at <a href="https://www.gov.uk/government/publications/building-amendment-regulations-2018-frequently-asked-questions/building-amendment-regulations-2018-frequently-asked-questions" target="_blank">https://www.gov.uk/government/publications/building-amendment-regulations-2018-frequently-asked-questions/building-amendment-regulations-2018-frequently-asked-questions</a>.</p>
answering member constituency South Derbyshire more like this
answering member printed Mrs Heather Wheeler more like this
question first answered
less than 2019-07-25T07:15:28.303Zmore like thismore than 2019-07-25T07:15:28.303Z
answering member
4053
label Biography information for Mrs Heather Wheeler more like this
tabling member
4268
label Biography information for Steve Reed remove filter
1141009
registered interest false more like this
date less than 2019-07-22more like thismore than 2019-07-22
answering body
Ministry of Housing, Communities and Local Government more like this
answering dept id 7 more like this
answering dept short name Housing, Communities and Local Government more like this
answering dept sort name Housing, Communities and Local Government more like this
hansard heading Buildings: Insulation more like this
house id 1 more like this
legislature
25259
pref label House of Commons more like this
question text To ask the Secretary of State for Housing, Communities and Local Government, with reference to Ministerial Statement, Building safety update, HCWS1757, whether his Department plans to (a) commission large scale fire tests on or (b) issue advice on B-rated and D-rated timber cladding following the BS 8414 test result on high pressure laminate cladding and combustible insulation. more like this
tabling member constituency Croydon North more like this
tabling member printed
Mr Steve Reed more like this
uin 280291 more like this
answer
answer
is ministerial correction false more like this
date of answer less than 2019-07-25more like thismore than 2019-07-25
answer text <p>The Independent Expert Advisory Panel (IEAP) has issued some advice to building owners with regards to non-Aluminium Composite Material cladding material the advice note is available at the following: <a href="https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765761/Expert_Panel_advice_note_on_non-ACM.pdf" target="_blank">https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765761/Expert_Panel_advice_note_on_non-ACM.pdf</a></p><p>The Department has currently no plan to commission a large scale test of timber cladding.</p> more like this
answering member constituency South Derbyshire more like this
answering member printed Mrs Heather Wheeler more like this
question first answered
less than 2019-07-25T07:15:06.893Zmore like thismore than 2019-07-25T07:15:06.893Z
answering member
4053
label Biography information for Mrs Heather Wheeler more like this
tabling member
4268
label Biography information for Steve Reed remove filter
1141112
registered interest false more like this
date less than 2019-07-22more like thismore than 2019-07-22
answering body
Ministry of Housing, Communities and Local Government more like this
answering dept id 7 more like this
answering dept short name Housing, Communities and Local Government more like this
answering dept sort name Housing, Communities and Local Government more like this
hansard heading Building Regulations: Fire Prevention more like this
house id 1 more like this
legislature
25259
pref label House of Commons more like this
question text To ask the Secretary of State for Housing, Communities and Local Government, whether his Department's technical review of the Building Regulations statutory guidance on fire safety (Approved Document B) will include a review of the regulations covering the self storage industry. more like this
tabling member constituency Croydon North more like this
tabling member printed
Mr Steve Reed more like this
uin 280352 more like this
answer
answer
is ministerial correction false more like this
date of answer less than 2019-07-25more like thismore than 2019-07-25
answer text <p>The statutory guidance on fire safety (Approved Document B) does already provide some provisions for self storage units.</p><p>The technical review of Approved Document B will be wide ranging and will cover all of the guidance in the document. We published a call for evidence which ended on 15 March 2019, we are currently analysing the results and will publish a response in due course.</p> more like this
answering member constituency South Derbyshire more like this
answering member printed Mrs Heather Wheeler more like this
question first answered
less than 2019-07-25T07:14:43.047Zmore like thismore than 2019-07-25T07:14:43.047Z
answering member
4053
label Biography information for Mrs Heather Wheeler more like this
tabling member
4268
label Biography information for Steve Reed remove filter
1140543
registered interest false more like this
date less than 2019-07-19more like thismore than 2019-07-19
answering body
Ministry of Housing, Communities and Local Government more like this
answering dept id 7 more like this
answering dept short name Housing, Communities and Local Government more like this
answering dept sort name Housing, Communities and Local Government more like this
hansard heading Buildings: Insulation more like this
house id 1 more like this
legislature
25259
pref label House of Commons more like this
question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 18 July 2019 to Question 268565 on Buildings: Insulation, if his Department will publish video footage of the BS 8414 test or tests on high pressure laminate cladding carried out on his Department's behalf by the Fire Protection Association. more like this
tabling member constituency Croydon North more like this
tabling member printed
Mr Steve Reed more like this
uin 279428 more like this
answer
answer
is ministerial correction false more like this
date of answer less than 2019-07-24more like thismore than 2019-07-24
answer text <p>The Department published on 18 July 2019 the test report and classification report. These reports contain the data gathered during the test as well as photographs taken before, during and after the test. This provides fuller information on the test than video footage.</p><p>These are available at : <a href="https://www.gov.uk/government/publications/fire-test-report-mhclg-bs-8414-hpl" target="_blank">https://www.gov.uk/government/publications/fire-test-report-mhclg-bs-8414-hpl</a></p> more like this
answering member constituency South Derbyshire more like this
answering member printed Mrs Heather Wheeler more like this
question first answered
less than 2019-07-24T16:37:21.437Zmore like thismore than 2019-07-24T16:37:21.437Z
answering member
4053
label Biography information for Mrs Heather Wheeler more like this
tabling member
4268
label Biography information for Steve Reed remove filter
1140291
registered interest false more like this
date less than 2019-07-18more like thismore than 2019-07-18
answering body
Ministry of Housing, Communities and Local Government more like this
answering dept id 7 more like this
answering dept short name Housing, Communities and Local Government more like this
answering dept sort name Housing, Communities and Local Government more like this
hansard heading High Rise Flats: Fire Prevention more like this
house id 1 more like this
legislature
25259
pref label House of Commons more like this
question text To ask the Secretary of State for Housing, Communities and Local Government, with reference to the Written Statement of 18 July 2019, on HCWS1757 on Building safety update, for what reasons his Department's data collection exercise is not covering high risk buildings other than residential blocks. more like this
tabling member constituency Croydon North more like this
tabling member printed
Mr Steve Reed more like this
uin 279064 more like this
answer
answer
is ministerial correction false more like this
date of answer less than 2019-07-23more like thismore than 2019-07-23
answer text <p>The data collection exercise launched on 18 July 2019 is part of an ongoing programme of work to enable the Department to build a more complete picture of high-rise residential buildings and the variety of external wall systems in use Government is collecting data on all external wall systems. The Government is collecting data on all external wall systems on residential buildings 18 metres and above, covering private and social (both local authority and housing association) stock, hotels and student accommodation. The data exercise is structured in such a way that additional questions could be added in the future if this would develop our data set to support this work. <br> <br> There remains a duty for those responsible for buildings to maintain safety of a premises (so far as the requirements are under their control) under the Regulatory Reform (Fire Safety) Order and the Housing Act.</p> more like this
answering member constituency North West Hampshire more like this
answering member printed Kit Malthouse more like this
question first answered
less than 2019-07-23T15:31:54.367Zmore like thismore than 2019-07-23T15:31:54.367Z
answering member
4495
label Biography information for Kit Malthouse more like this
tabling member
4268
label Biography information for Steve Reed remove filter