Linked Data API

Show Search Form

Search Results

1134143
star this property registered interest false more like this
star this property date less than 2019-06-24more like thismore than 2019-06-24
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 6 June 2019 to Question 259244 on Buildings: Insulation, whether the BS 8414 test of a High Pressure Laminate cladding system has been carried out; and if he will make a statement. more like this
star this property tabling member constituency Croydon North more like this
star this property tabling member printed
Mr Steve Reed more like this
star this property uin 268565 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-18more like thismore than 2019-07-18
unstar this property answer text <p>The Large scale BS 8414 test including Class B-s1,d0 High Pressure Laminate panels with stone wool insulation was carried out on the 11 July 2019 and the test report is now available online.</p><p>This was announced in the Written Minsiterial Statement on 18 July HCWS1757 that can be found here: <a href="https://www.parliament.uk/business/publications/written-questions-answers-statements/written-statement/Commons/2019-07-18/HCWS1757/" target="_blank">https://www.parliament.uk/business/publications/written-questions-answers-statements/written-statement/Commons/2019-07-18/HCWS1757/</a>.</p> more like this
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property question first answered
less than 2019-07-18T15:18:37.083Zmore like thismore than 2019-07-18T15:18:37.083Z
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
star this property previous answer version
125805
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
unstar this property tabling member
4268
unstar this property label Biography information for Steve Reed more like this
1140169
star this property registered interest false more like this
star this property date less than 2019-07-18more like thismore than 2019-07-18
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 17 July 2019 to Question 276197 on Buildings: Insulation, in the event that high-pressure laminate cladding fails a BS 8414 test for the same reasons aluminium composite material (ACM) cladding did, whether he would still consider ACM cladding to be wholly exceptional. more like this
star this property tabling member constituency Croydon North more like this
star this property tabling member printed
Mr Steve Reed more like this
star this property uin 279061 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-23more like thismore than 2019-07-23
unstar this property answer text <p>On 18 July 2019 the Independent Expert Advisory Panel (IAEP) issued an advice note to building owners. In this advice note the IAEP states the following:</p><p> </p><p><em>“The view of the Expert Panel is that the level of risk from unsafe HPL systems is not as high a risk as unsafe systems using ACM Category 3 panels. Therefore, the Expert Panel remains clear that the immediate removal of unsafe systems using ACM Category 3 panels should be an absolute priority of focus for building owners and the sector, followed by immediate action to remediate unsafe HPL systems. For the avoidance of doubt both the removal of unsafe ACM Category 3 panels and action to remediate unsafe HPL systems should be carried out as soon as possible.”</em></p><p> </p><p>The full advice note is available at <a href="https://gbr01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fassets.publishing.service.gov.uk%2Fgovernment%2Fuploads%2Fsystem%2Fuploads%2Fattachment_data%2Ffile%2F818184%2FAdvice_note_on_use_of_HPL_panels_in_external_wall_systems.pdf&amp;data=02%7C01%7CCharles-Elie.Romeyer%40communities.gov.uk%7C3985d5850bdf4c4a8cc708d70e7ede45%7Cbf3468109c7d43dea87224a2ef3995a8%7C0%7C0%7C636993810367162667&amp;sdata=FT2Xkf%2BNFfUXmD%2F0%2FWdxtvozJg4d3KitxBTL5UxkccY%3D&amp;reserved=0" target="_blank">https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/818184/Advice_note_on_use_of_HPL_panels_in_external_wall_systems.pdf</a></p>
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property question first answered
less than 2019-07-23T15:23:40.313Zmore like thismore than 2019-07-23T15:23:40.313Z
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
unstar this property tabling member
4268
unstar this property label Biography information for Steve Reed more like this
1140262
star this property registered interest false more like this
star this property date less than 2019-07-18more like thismore than 2019-07-18
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 3 July 2019 to Question 267773 on Buildings: Insulation, whether his Department's engagement with (a) local authorities, (b) housing associations and (c) industry includes requests for information on the number of buildings covered in HPL cladding. more like this
star this property tabling member constituency Croydon Central more like this
star this property tabling member printed
Sarah Jones more like this
star this property uin 279136 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-23more like thismore than 2019-07-23
unstar this property answer text <p>On 18 July 2019, the Government asked local authorities and housing associations to undertake a data collection exercise on the external wall systems of their high rise residential buildings that are 18 metres or above. This includes high rise residential buildings that are clad in High Pressure Laminate.</p> more like this
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property grouped question UIN 279137 more like this
star this property question first answered
less than 2019-07-23T15:27:10.353Zmore like thismore than 2019-07-23T15:27:10.353Z
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
unstar this property tabling member
4631
unstar this property label Biography information for Sarah Jones more like this
1140265
star this property registered interest false more like this
star this property date less than 2019-07-18more like thismore than 2019-07-18
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 17 June 2019 to Question 262396 on Buildings: Insulation, whether his Department took steps to estimate the number of buildings with HPL cladding after the failed BS8414 fire test on that cladding. more like this
star this property tabling member constituency Croydon Central more like this
star this property tabling member printed
Sarah Jones more like this
star this property uin 279137 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-23more like thismore than 2019-07-23
unstar this property answer text <p>On 18 July 2019, the Government asked local authorities and housing associations to undertake a data collection exercise on the external wall systems of their high rise residential buildings that are 18 metres or above. This includes high rise residential buildings that are clad in High Pressure Laminate.</p> more like this
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property grouped question UIN 279136 more like this
star this property question first answered
less than 2019-07-23T15:27:10.4Zmore like thismore than 2019-07-23T15:27:10.4Z
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
unstar this property tabling member
4631
unstar this property label Biography information for Sarah Jones more like this
1140277
star this property registered interest false more like this
star this property date less than 2019-07-18more like thismore than 2019-07-18
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 17 June 2019 to Question 262396 on Buildings: Insulation, what type of combustible insulation was combined with HPL cladding for the BS8414 test. more like this
star this property tabling member constituency Croydon Central more like this
star this property tabling member printed
Sarah Jones more like this
star this property uin 279138 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-23more like thismore than 2019-07-23
unstar this property answer text <p>The insulation used during the test was a combustible phenolic foam insulation.</p> more like this
star this property answering member constituency North West Hampshire more like this
star this property answering member printed Kit Malthouse more like this
star this property question first answered
less than 2019-07-23T15:25:03.217Zmore like thismore than 2019-07-23T15:25:03.217Z
star this property answering member
4495
star this property label Biography information for Kit Malthouse more like this
unstar this property tabling member
4631
unstar this property label Biography information for Sarah Jones more like this
1140543
star this property registered interest false more like this
star this property date less than 2019-07-19more like thismore than 2019-07-19
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, pursuant to the Answer of 18 July 2019 to Question 268565 on Buildings: Insulation, if his Department will publish video footage of the BS 8414 test or tests on high pressure laminate cladding carried out on his Department's behalf by the Fire Protection Association. more like this
star this property tabling member constituency Croydon North more like this
star this property tabling member printed
Mr Steve Reed more like this
star this property uin 279428 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-24more like thismore than 2019-07-24
unstar this property answer text <p>The Department published on 18 July 2019 the test report and classification report. These reports contain the data gathered during the test as well as photographs taken before, during and after the test. This provides fuller information on the test than video footage.</p><p>These are available at : <a href="https://www.gov.uk/government/publications/fire-test-report-mhclg-bs-8414-hpl" target="_blank">https://www.gov.uk/government/publications/fire-test-report-mhclg-bs-8414-hpl</a></p> more like this
star this property answering member constituency South Derbyshire more like this
star this property answering member printed Mrs Heather Wheeler more like this
star this property question first answered
less than 2019-07-24T16:37:21.437Zmore like thismore than 2019-07-24T16:37:21.437Z
star this property answering member
4053
star this property label Biography information for Mrs Heather Wheeler more like this
unstar this property tabling member
4268
unstar this property label Biography information for Steve Reed more like this
1140804
star this property registered interest false more like this
star this property date less than 2019-07-22more like thismore than 2019-07-22
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, whether Class B High Pressure Laminate cladding with combustible insulation can be reused on a building in the event that the combustible insulation is replaced. more like this
star this property tabling member constituency Croydon North more like this
star this property tabling member printed
Mr Steve Reed more like this
star this property uin 280244 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-25more like thismore than 2019-07-25
unstar this property answer text <p>The Department published in April 2019 a Frequently asked Question on the Government website one of which answer the question “How do the Building (Amendment) Regulations 2018 affect buildings undergoing remediation?”</p><p>The requirement is that building work on such buildings must be carried out so that only materials which achieve European Classification A1 or A2-s1, d0 become part of an external wall or specified attachment (as defined in regulation 2) unless covered by one of the exemptions in the regulations.</p><p>This means that materials which are already part of the external wall, or are existing specified attachments, and are not becoming part of the wall are not covered by the ban (unless there is a change of use). However, during this process care must be taken to ensure that the building is no less compliant in relation to building regulation requirements than before the work was carried out (e.g. cavity barrier).</p><p>The full list of frequently asked questions is available at <a href="https://www.gov.uk/government/publications/building-amendment-regulations-2018-frequently-asked-questions/building-amendment-regulations-2018-frequently-asked-questions" target="_blank">https://www.gov.uk/government/publications/building-amendment-regulations-2018-frequently-asked-questions/building-amendment-regulations-2018-frequently-asked-questions</a>.</p>
star this property answering member constituency South Derbyshire more like this
star this property answering member printed Mrs Heather Wheeler more like this
star this property question first answered
less than 2019-07-25T07:15:28.303Zmore like thismore than 2019-07-25T07:15:28.303Z
star this property answering member
4053
star this property label Biography information for Mrs Heather Wheeler more like this
unstar this property tabling member
4268
unstar this property label Biography information for Steve Reed more like this
1141009
star this property registered interest false more like this
star this property date less than 2019-07-22more like thismore than 2019-07-22
star this property answering body
Ministry of Housing, Communities and Local Government more like this
star this property answering dept id 7 more like this
star this property answering dept short name Housing, Communities and Local Government more like this
star this property answering dept sort name Housing, Communities and Local Government remove filter
star this property hansard heading Buildings: Insulation remove filter
star this property house id 1 more like this
star this property legislature
25259
star this property pref label House of Commons more like this
star this property question text To ask the Secretary of State for Housing, Communities and Local Government, with reference to Ministerial Statement, Building safety update, HCWS1757, whether his Department plans to (a) commission large scale fire tests on or (b) issue advice on B-rated and D-rated timber cladding following the BS 8414 test result on high pressure laminate cladding and combustible insulation. more like this
star this property tabling member constituency Croydon North more like this
star this property tabling member printed
Mr Steve Reed more like this
star this property uin 280291 more like this
star this property answer
answer
unstar this property is ministerial correction false more like this
star this property date of answer less than 2019-07-25more like thismore than 2019-07-25
unstar this property answer text <p>The Independent Expert Advisory Panel (IEAP) has issued some advice to building owners with regards to non-Aluminium Composite Material cladding material the advice note is available at the following: <a href="https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765761/Expert_Panel_advice_note_on_non-ACM.pdf" target="_blank">https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765761/Expert_Panel_advice_note_on_non-ACM.pdf</a></p><p>The Department has currently no plan to commission a large scale test of timber cladding.</p> more like this
star this property answering member constituency South Derbyshire more like this
star this property answering member printed Mrs Heather Wheeler more like this
star this property question first answered
less than 2019-07-25T07:15:06.893Zmore like thismore than 2019-07-25T07:15:06.893Z
star this property answering member
4053
star this property label Biography information for Mrs Heather Wheeler more like this
unstar this property tabling member
4268
unstar this property label Biography information for Steve Reed more like this